C2G 88513 2 Metre UK Power Cable (IEC320C13 to BS 1363) 6 Foot Kettle Lead/Power Cord, Black

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

These cables are sometimes informally referred to as a "kettle cord" or "kettle lead", but the C13/14 connectors are only rated for 70°C (158°F): a device such as a kettle requires the C15/16 connector, rated for 120°C (248°F). A similar but polarized connector has been made, but is not part of the standard. Sometimes called C7P, it is asymmetrical, with one side squared. Unpolarized C7 connectors can be inserted into the polarized inlets; however, doing so might be a safety risk if the device is designed for polarized power. Although not specified by IEC 60320, and not clear whether any formal written standard exists, the most common wiring appears to connect the squared side to the neutral, and the rounded to the hot line. [23] [24] Note: Clause 9.5 was added to IEC 60320-1:2015, this requires that "It shall not be possible to engage a part of a non-standard appliance coupler with a complementary part of an appliance coupler complying with the standard sheets in any part of IEC 60320." UL certification E152635 covering YC-12 C13, YC-20 C15 and YP-32 C14 connectors. Note that the manufacturer's YC-20 label contains an error; the wire gauges (18, 16, 14) are repeated in the "current rating" column; the UL certification contains the correct values (10A, 13A, 15A). Retrieved 2014-09-24.

IEC 60320-3: Standard sheets and gauges. [4] First published October 31, 2014, this part initially included the standard sheets for both appliance couplers and interconnection couplers. In a 2018 amendment, the standard sheets for the IP couplers defined by 60320-2-3 were added. [9] For appliance couplers the various coupler outlines are designated using a combination of letters and numbers, e.g., "C14". The connector supplies power to the appliance inlet. The appliance inlet is designated by the even number one greater than the number assigned to the connector, so a C1 connector mates with a C2 inlet, and a C15A mates with a C16A. Interconnection couplers have single letter designators, e.g., "F". They consist of a plug connector and an appliance outlet. The plug connector is the part integral with, or intended to be attached to, the cord, and the appliance outlet is the part integrated with or incorporated into the appliance or equipment or intended to be fixed to it, and from which the supply is obtained. a b "IEC 60320-3:2014+AMD1:2018+AMD2:2022 CSV | IEC Webstore". webstore.iec.ch . Retrieved 2023-05-13. The C15 is very similar to the C13 connector but has a groove between the 2 pins, this is known as a hot condition connector. Rated for higher temperatures than the C13. C5 Cloverleaf Power Cables

In European countries the C15/C16 coupler has replaced and made obsolete the formerly common types of national appliance coupler in many applications. We’ve also got electrical kettles featuring water filters for the purest brew. Go for a cream one to match your kitchen décor, or opt for a practical filter to help remove water impurities.

Connector: "part of the appliance coupler integral with, or intended to be attached to, one cord connected to the supply". The dimensions and tolerances for connectors, appliance inlets, appliance outlets and plug connectors are given in standard sheets, which are dimensioned drawings showing the features required for safety and interchangeability. Appliance inlet: "part of the appliance coupler integrated as a part of an appliance or incorporated as a separate part in the appliance or equipment or intended to be fixed to it".A cable consisting of a C13 and an E interconnection connector is commonly mislabeled as an "extension cord", as although that is not the intended purpose, it can be used as such. They are also commonly mislabeled as C14 instead of E. Power cords are defined as any power cable which has had a connector installed prior to sale. There are versions that may have one connector and an unterminated end. Some assemblies may have a connector a plug. And some assemblies will even have 2 connectors (IEC lead extension). Depending on the application, there are various types to suit the needs. What are these cable assemblies used for? The mains appliance couplers are all engineered to connect an appliance via a power cord to mains power. The C6 inlet is used on laptop power supplies and portable projectors, as well as on some desktop computers, some LCD monitors and recent LCD televisions from LG. This kind of coupler is used by Roland Corporation for a couple of synthesizer and drum-computer models (for example: TR-909, D-50) and by Revox for many older models of their hi-fi equipment (for example, A76, A77, A78, B77, B225). Was also used heavily on Marantz hi-fi equipment in the 1980s and 1990s.

The C17/C18 coupler is often used in audio applications where a floating ground is maintained to eliminate hum caused by ground loops. Other common applications are the power supplies of Xbox 360 game consoles, replacing the C15/C16 coupler employed initially, and large CRT televisions manufactured by RCA in the early 1990s.When buying partner items like this one, your contract of sale will be with our Range Plus Partner instead of us.

IEC - SC 23G Dashboard > Projects / Publications: Work programme, Publications, Stability Dates, Project files". www.iec.ch . Retrieved 2023-05-12. Xbox One Power Supply | Xbox One Console". support.xbox.com. Archived from the original on 2016-11-26 . Retrieved 2016-11-25.One arbitrarily chosen example of a 1500W PSU with a C14 input is the Enermax MAXREVO 1500 W 80+ Gold. It manages to fit within the 15A input current limit because of its 80 Plus gold efficiency. Pin temperature is measured where the pin projects from the engagement surface. The maximum permitted pin temperatures, are 70°C (158°F), 120°C (248°F), and 155°C (311°F), respectively (the higher temperatures are not applicable to interconnection couplers). The pin temperature is determined by the design of the appliance, and its interior temperature, rather than by its ambient temperature. Typical applications with increased pin temperatures include appliances with heating coils such as ovens or electric grills. It is generally possible to use a connector with a higher rated temperature with a lower rated appliance inlet, but the keying feature of the inlet prevents use of a connector with a lower temperature rating. IEC 60320-1: General Requirements [1] specifies two- pole and two-pole with earth couplers intended for the connection of a mains supply cord to electrical appliances. Beginning with the IEC 60320-1:2015 edition, [5] this part also specifies interconnection couplers which enable the connection and disconnection of an appliance to a cord leading to another appliance, incorporating IEC 60320-2-2. At the same time, this part of the standard no longer includes standard sheets which were moved to a new part: IEC 60320-3. IEC 60320-2-2: Interconnection couplers for household and similar equipment. This section was withdrawn in January 2016. The general requirements for these items were incorporated into IEC 60320-1 and the standard sheets were moved to IEC 60320-3.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.